From the Loftsmith Workshop

Radiator TRV adapter M30x1.5 for Danfoss RA, RAV, RAVL, M28

For when your radiator valve takes a different head than the one you've bought. This adapter has an M30x1.5 thread on top and a clamp that grips the valve neck below, with a small pin in the centre. Set the neck width and pin length to match your valve.

3 parts · 9 g · 31 × 88 × 55 mm

by Loftsmith Workshop

Teal threaded adapter with a small orange pin, above a grey valve body and a loose orange ring
Loading the 3D view
Loading the 3D view
No adjustable sizes

Ask for the sizes you want to tweak, e.g. “make the width adjustable”.

Parts

  • adapter · PETG · Upright, valve (clamp) end on the bed, thread up; no supports

    30.6 x 38.5 x 24.5 mm at defaults; about 7 g and 15 min at 2 walls/15%. Use 4 walls so the thread prints as solid plastic.

  • pin-extender · PETG · Top face on the bed, pin hole facing up

    6.5 mm cap with a 3.2 mm x 3.7 mm deep hole for a 3 mm valve pin; adds the Pin extension slider value (1 to 15 mm). Under 1 g, about 5 min.

  • fit-ring · PETG · Flat on the bed

    6 mm tall copy of the clamp bore with its keys (or of the M28 thread). About 2 g and 7 min. Print it first to check the fit; turn it off with the fit-test ring toggle.

Print settings

Layer height
0.2 mm
Walls
4 walls recommended (the page stats use 2)
Infill
25% recommended (the page stats use 15%)
Supports
None
Notes
PETG for radiators at normal temperatures; ASA if the valve body is too hot to hold your hand on; never PLA. At the page settings (2 walls, 15% infill) all three parts are about 9 g and 27 min. At the recommended 4 walls and 25% infill they are about 13 g and 38 min. Print the fit ring first (about

Hardware

  • M3 x 16 socket head cap screw · Clamp screw at the default M3 setting. With the M4 choice use M4 x 20. Not needed for the M28 thread version.
  • M3 hex nut · Goes in the hex pocket on the clamp ear (M4 nut with the M4 choice). Not needed for the M28 version.
  • 2.5 mm hex key · To tighten the M3 clamp screw (3 mm key for M4).

Assembly

  1. Pick your valve type, or choose Measured clamp and enter the neck diameter you measured with calipers. Count the notches on the valve neck and set Notches (0 for a plain neck).
  2. Print the fit ring and push it onto the valve neck (screw it on for M28). It should slide on with a little play and its keys should drop into the notches. If it is too tight, raise Clamp clearance; if the keys don't line up, change Notches or set it to 0.
  3. Print the adapter and the pin extender. Press the nut into the hex pocket on the clamp ear.
  4. Take off the old thermostat head. Push the pin extender onto the valve pin.
  5. Slide the adapter down over the neck until the neck top meets the stop inside, with the keys in the notches. Tighten the clamp screw with a hex key until snug. The slit should still be about 1 mm open.
  6. Screw the smart thermostat onto the M30 thread hand-tight and run its calibration.
  7. If the thermostat reports it cannot close the valve (check your thermostat's manual for its valve-not-closing error), print a longer pin extender: raise Pin extension in 0.5 mm steps.

Good to know

  • The adapter carries no water pressure; the valve insert does. If the clamp slips or the extender is too short, the radiator can stay on or off, so check the room temperature over the first day.
  • Valve families have variants. Measure your neck and count its notches before printing, and print the fit ring first. The keys are 2 mm wide, 1 mm deep and 4 mm long at the top of the clamp. If your notches are different, set Notches to 0.
  • How far the thermostat's plunger reaches varies by model. With the other sliders at their defaults, the valve top sits this far below the thermostat seat face: 5.9 mm for RA 23 mm, 12.7 mm for RAVL 25.5 mm, 17.0 mm for RAV 34 mm and 13.2 mm for M28 x 1.5. The RAVL, RAV and M28 versions will likely n
  • The clamp-strength checks rest on assumed numbers: a 120 N actuator push, 300 N of screw tension (400 N for M4) and a friction coefficient of 0.3. They are engine estimates, not physical tests, and their margins are modest (283 N grip against 240 N demand; 12.7 MPa ear bending against a 15 MPa allow
  • Printed thread fit depends on your printer. If the thermostat nut is tight, raise Thread allowance by 0.1 mm. If it feels loose, lower it (minimum 0.4 mm).
  • Use PETG for radiators at normal temperatures, and ASA if the valve body is too hot to hold your hand on. Never use PLA. A screw clamp under constant load can creep when hot, so re-check the clamp screw after the first week of heating.

Comments