From the Loftsmith Workshop

Pipe lagging elbow and tee cover for 15/22/28 mm pipe

Wraps the awkward bends in your pipework, where foam tube won't turn the corner. It's two halves joined by a little hinge, so you open it, lay the pipe in and close it up with the clips. Set your pipe size and how thick the wall is.

2 parts · 42 g · 112 × 145 × 40 mm

by Loftsmith Workshop

Hinged two-part curved pipe cover lying open with a copper-coloured pipe bend resting in one half
Loading the 3D view
Loading the 3D view
No adjustable sizes

Ask for the sizes you want to tweak, e.g. “make the width adjustable”.

Parts

  • base-half · PETG · Cup-up on its flat spine, as modelled; carries the hinge pin and the upright thumb clips

    Prints together with lid-half as one object (print group 'cover'); ~22 g, ~36 min at 2 walls/15%.

  • lid-half · PETG · Cup-up on its flat spine beside the base half, opened 180 degrees on the hinge, as modelled

    Prints in place on the base half's pin; ~20 g, ~31 min at 2 walls/15%. PETG because the clips have to flex and loft pipes see summer heat.

Print settings

Layer height
0.2 mm
Walls
2 (the page default); 3 walls gives stiffer clips: ~60 g, ~1 h 37 min
Infill
15%
Supports
None. Both halves sit on their flat spines and the clip ledges are 2.6 mm or less.
Notes
About 44 g of PETG and 1 h 10 min at 2 walls/15% for the default 90-degree elbow (112 x 145 x 40 mm, fits a 180 mm bed). Export as 3MF so the two halves stay one object and the hinge gaps are kept. Use ASA instead of PETG for central-heating pipes in hot spaces.

Assembly

  1. Print both halves as one object. Once it's off the bed, bend the lid half back and forth a few times to free the hinge. If it stays stuck, reprint with the Hinge radial gap slider at 0.5 mm.
  2. Fit the lagging round the joint as usual (mitred or butted). The cover only has to close the gap, so the cut does not need to be neat.
  3. Lay the lagged elbow or tee into the base half, the one with the upright clips.
  4. Fold the lid half over and press down on each latch block until the clip clicks into its groove.
  5. To open it, pull each clip's flared thumb tab about 2 mm outward and lift the lid.

Good to know

  • The cover closes the gap in the lagging at a bend or tee. It does not make a pipe frost-proof and is not a substitute for proper insulation or heating.
  • The hinge, clips and squeeze were checked in the CAD engine only. Print one and test the fit on your own lagging before printing a batch. Foam brands vary in outside diameter, so adjust the Squeeze slider to suit.
  • On tight soldered or push-fit elbows the sleeve is swept at the tightest radius it can hold (24 mm for 15 mm pipe with 13 mm lagging), so the pipe sits up to a few mm off the sleeve axis and the foam takes that up.
  • It is a cover, not a pipe clip. Don't use it to support or fix pipes.
  • PETG softens at about 75 °C. Use ASA for central-heating pipes in hot cupboards or lofts.
  • The sleeve slider starts at 25 mm because the tee needs that much room for its three clips.

Comments